Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Einstein (Sao Paulo) ; 12(3): 318-22, 2014 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-25295453

RESUMO

OBJECTIVE: To investigate the effects of different transcutaneous electrical nerve stimulation frequencies in nociception front of a pressure pain threshold and cold in healthy individuals. METHODS: Twenty healthy subjects were divided into four groups, all of which have gone through all forms of electrical stimulation at different weeks. Assessments were pre and post-therapy, 20 and 60 minutes after stimulation. To evaluate the pressure pain threshold, an algometer was used with one tapered tip, pressing the hypothenar region until voluntary report the word "pain". Cold pain intensity was assessed by immersion in water at 5°C for 30 seconds; at the end, the subject was asked to quantify the pain intensity on a Visual Analog Scale for Pain. For electrical stimulation, two electrodes were used near the elbow, for 20 minutes, with an intensity strong, but not painful. The frequency was in accordance with the group: 0Hz (placebo); 7Hz; 100Hz; and 255Hz. RESULTS: Both for the assessment of pressure pain threshold as the cold pain intensity, there was no significant difference (p>0.05). CONCLUSION: We conclude that the use of transcutaneous electrical nerve stimulation on dermatomes C6 to C8 produced no significant change in pressure pain threshold or cold discomfort.


Assuntos
Medição da Dor , Limiar da Dor/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Análise de Variância , Temperatura Baixa/efeitos adversos , Feminino , Humanos , Masculino , Pressão/efeitos adversos , Distribuição Aleatória , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
2.
Einstein (Säo Paulo) ; 12(3): 318-322, Jul-Sep/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-723921

RESUMO

Objective To investigate the effects of different transcutaneous electrical nerve stimulation frequencies in nociception front of a pressure pain threshold and cold in healthy individuals. Methods Twenty healthy subjects were divided into four groups, all of which have gone through all forms of electrical stimulation at different weeks. Assessments were pre and post-therapy, 20 and 60 minutes after stimulation. To evaluate the pressure pain threshold, an algometer was used with one tapered tip, pressing the hypothenar region until voluntary report the word “pain”. Cold pain intensity was assessed by immersion in water at 5°C for 30 seconds; at the end, the subject was asked to quantify the pain intensity on a Visual Analog Scale for Pain. For electrical stimulation, two electrodes were used near the elbow, for 20 minutes, with an intensity strong, but not painful. The frequency was in accordance with the group: 0Hz (placebo); 7Hz; 100Hz; and 255Hz. Results Both for the assessment of pressure pain threshold as the cold pain intensity, there was no significant difference (p>0.05). Conclusion We conclude that the use of transcutaneous electrical nerve stimulation on dermatomes C6 to C8 produced no significant change in pressure pain threshold or cold discomfort. .


Objetivo Investigar os efeitos de diferentes frequências da estimulação elétrica nervosa transcutânea na nocicepção, frente a um estímulo doloroso pressórico e ao frio, em indivíduos saudáveis. Métodos Participaram 20 indivíduos saudáveis, divididos em 4 grupos, sendo que todos passaram por todas as formas de eletroestimulação, em semanas diferentes. As avaliações ocorreram nos seguintes períodos: pré-aplicação, pós-aplicação, 20 e 60 minutos após a eletroestimulação. Para avaliar o limiar de dor à pressão, foi utilizado um algômetro com ponta afilada, pressionando na região hipotenar, até o voluntário relatar a palavra “dor”. A intensidade de dor ao frio foi avaliada por meio de imersão em água a 5°C, durante 30 segundos; ao final, pediu-se para que o indivíduo quantificasse a intensidade álgica em uma Escala Visual Analógica de Dor. Para a eletroestimulação, foram utilizados dois eletrodos próximos ao cotovelo, durante 20 minutos, com intensidade referida como forte, porém não dolorosa. A frequência esteve de acordo com o grupo: 0Hz (placebo); 7Hz; 100Hz; e 255Hz. Resultados Tanto para a avaliação do limiar de dor à pressão quanto da intensidade ao frio, não houve diferença significativa (p>0,05). Conclusão O uso da estimulação elétrica nervosa transcutânea, sobre os dermátomos de C6 a C8, não produziu alteração significativa no limiar de dor à pressão e nem no desconforto ao frio. .


Assuntos
Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Medição da Dor , Limiar da Dor/fisiologia , Estimulação Elétrica Nervosa Transcutânea/métodos , Análise de Variância , Temperatura Baixa/efeitos adversos , Pressão/efeitos adversos , Distribuição Aleatória , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...